Commercial HEATCRAFT Refrigerator Repair in Sunnyvale: Refrigerant Leak Fix

Commercial Refrigerator HEATCRAFT — Refrigerant Leak Detection and Repair
Client: Ben | Sunnyvale
✅ In early May, we were contacted by Ben, the manager of one of the convenience stores located at a modern Loop Neighborhood gas station in Sunnyvale. He reported elevated temperatures in the commercial HEATCRAFT refrigerator (model MOH020D73CFTS).
In high-traffic locations like this—where perishable goods are stored and quick service is essential—consistent refrigeration performance is crucial for daily operations.
✅ During the initial diagnostics, a refrigerant leak was identified in the section between the solenoid valve and the TXV (thermostatic expansion valve).
✅ The client approved the proposed repair plan, and our team carried out the following work:
- Replaced the damaged section of refrigerant piping
- Performed a high-pressure leak test — no pressure loss detected
- Properly evacuated and recharged the system with 9 lb of fresh refrigerant
- Total repair cost was approximately $1,000
✅ After completion, the unit reached and maintained stable temperature levels, resuming normal operation.
Additionally, during the service visit we identified:
- An intermittent signal issue from the low-pressure switch, which depends on wire positioning.
- The wiring was secured to minimize the risk of failure.
- While this issue does not currently impact performance, we recommend replacing the sensor as a preventive measure to ensure long-term reliability.