The customer reported that the unit was not maintaining proper temperature, with the internal temperature around 50°F. This posed a risk to stored products and daily business operations.
Diagnostic Findings
- ✅ Significant ice buildup on the evaporator due to warm, humid air entering the unit
- ✅ Upper lids were frequently left open
- ✅ A large opening allowed direct airflow into the refrigerated compartment
The issue was not a mechanical failure, but an operational/exploitation problem.
Actions Performed by Our Team
- ✅ Performed a partial defrost cycle to remove main ice buildup and restore airflow
- ✅ Cleared visible ice and moisture from the evaporator to reduce the risk of overheating
- ✅ Trained staff on proper defrost procedures to safely defrost the unit without damage
- ✅ Demonstrated correct operation practices: keeping lids closed, minimizing open time, monitoring temperature and cooling levels
- ✅ Developed simple daily procedures for the staff: checking temperature, visually inspecting the evaporator, reducing warm air infiltration
These measures stabilized the unit, protected the products, and allowed the business to continue operating without downtime.
Recommendations for Staff
- ✅ Always keep lids closed
- ✅ Ensure all openings into the refrigerated compartment are sealed
- ✅ Perform regular manual defrost according to instructions
- ✅ Monitor temperatures over the next 24–48 hours
- ✅ If issues recur, request additional inspection